Why roof installs need extra protection
A full storage tank holds well over a hundred litres. If it leaks above a plasterboard ceiling, you find out when the ceiling comes down. That is why the plumbing standard, AS/NZS 3500.4, requires protection where a leak could damage the building.
The safe tray and safe waste
For a storage system installed in a roof space, the standard calls for a safe tray under the tank. The tray drains to a safe waste, which is a dedicated pipe that carries leaked water out of the building to a visible spot where you will notice it. The tray should sit on a solid platform that can carry the full weight of the tank.
- The tray must be sized to suit the tank.
- The safe waste must fall continuously to its outlet.
- The tank must be properly supported, not balanced on rafters.
Relief valve drains are separate
The drain line from the relief valve must not discharge into the safe tray. It has its own line. In Queensland the relief drain should end close to ground level in a visible position. It must not run onto the roof or into the gutter.
Signs your roof install is risky
- Stained ceiling directly under the tank.
- No tray, or a tray with no drain pipe.
- Water running from a pipe outlet outside that you cannot explain.
- A tank older than about ten years sitting on a rotted platform.
If you are replacing an older roof system, ask whether it should move to ground level. It is usually safer and easier to service. Read more about how long hot water systems last on the Coast.