First, find where the water is coming from
Dry the area with a towel and watch. Water that appears at the top of the tank and runs down is usually a fitting, a valve or the relief line. Water that appears at the base seam, or weeps through the outer casing, is almost always the inner tank.
The relief valve
Every storage tank has a temperature and pressure relief valve with a copper drain pipe. A slow drip while heating is normal. A constant stream is not. A stuck relief valve is a quick, cheap replacement. Read our guide on relief valve dripping if that is your symptom.
The drain cock and fittings
The small tap at the bottom of the tank and the hot and cold connections at the top can weep over time. Coastal air corrodes brass fittings. These are repairable. We replace the fitting, reseal and test.
Not sure? Call 0428 411 487 and send a photo. We will tell you straight.
The tank itself
Storage tanks are steel lined with vitreous enamel or stainless. The sacrificial anode protects the steel. When the anode is gone, the tank rusts from the inside. Eventually it pin holes and leaks through the insulation and out the bottom. There is no repair for a split tank. The system is replaced.
What to do right now
Turn off the cold water isolation valve on the pipe going into the tank. Turn off the power at the switchboard or the gas at the unit. This stops the leak getting worse and protects the element from running dry. Then call.
How fast can it be replaced?
We stock common tank sizes and can usually swap a like for like unit the same day. If you want to change to gas, heat pump or continuous flow, we quote that on the spot and book it in. A split tank is also your chance to avoid the same problem again: ask about anode checks on the new system.