Cause 1: a leak somewhere
The pump holds pressure in the pipes. If anything lets water out, pressure drops and the pump starts to top it up. A running toilet, a dripping tap, a weeping irrigation valve or a split pipe under the lawn will all do it. A pump that runs when no tap is open is nearly always a leak. Turn off the isolation valve at the house and watch. If the pump stops cycling, the leak is in the house. If it keeps going, it is between the pump and the valve.
Cause 2: a failed check valve
The check valve, or non return valve, stops water flowing back from the pipes into the tank when the pump stops. If it sticks open, water drains back, pressure drops and the pump restarts. Over and over. It is a cheap part and a short job.
Cause 3: a waterlogged pressure tank
Many pumps have a small pressure tank with an air bladder inside. It gives the pump a cushion so it does not start for every glass of water. When the bladder fails or loses its air charge, the cushion is gone and the pump starts and stops rapidly, every time a tap is cracked. Check the air pressure at the valve on top. If water comes out, the bladder is gone.
Pump cycling now? Call 0428 411 487 before it burns out.
Cause 4: a faulty pressure controller
Modern pumps use an electronic controller that senses flow and pressure. They fail, and when they do the pump either will not stop or will not start. If the leak test and the check valve both pass, the controller is next. On a pump more than 8 years old, replacing the controller may cost more than it is worth.
Cause 5: a blocked inlet or low tank
If the pump is sucking air because the tank is nearly empty or the inlet strainer is blocked, it loses prime, cuts out on dry run protection, cools, tries again and repeats. Check the tank level and the strainer.
Why it matters
Every start is wear on the motor, the capacitor and the switch. A cycling pump that would have lasted 10 years can be dead in two. The fix is usually a fraction of the cost of a new pump.
What we do
Isolate and test for leaks, check the non return valve, test the pressure tank, check the controller and the strainer. Most pump cycling calls are fixed in one visit.
Allied Plumbing services and replaces pumps across the Sunshine Coast and Noosa. QBCC Licence 15589829. MPAQ member. 15 years in the trade. Call 0428 411 487 or get in touch online.